測試條件 Test Conditions
所有特性測試,在環(huán)境溫度30℃±3℃條件下進(jìn)行,在此期間溫度變化不允許達(dá)到+5℃和到極限范圍。
All electrical tests are conducted at ambient temperature of?30℃±3℃.??The ambient temperature is not allowed to vary more than 5℃ during the test, and must be within these limits.
分?jǐn)嗄芰reaking Capacity
熔斷體的分?jǐn)嗄芰?yīng)能達(dá)到下表規(guī)定的相應(yīng)的各種安全認(rèn)證的分?jǐn)嗄芰σ蟆1kU(xiǎn)絲分?jǐn)嚯娐泛螅kU(xiǎn)絲管不應(yīng)破裂、銅帽飛脫、且銅帽兩端的絕緣電阻不小于0.1MΩ。
| 額定電壓 ?Rated Voltage | 額定電流 Rated Current | ?分?jǐn)嚯娏?br/> Breaking Capacity |
| 690V? | 1A-63A | DC 50KA |
技術(shù)數(shù)據(jù)Techinical Data
| 編號 Part Number | 額定電流 Current Rating (Ampers) | 能量積分 Energy Integrals I2T(A2S) | 功耗 Power Loss(W) |
| 14C-2200-G | 20 | 448 | 12.7 |
| 14C-2300-G | 30 | 787.2 | 7.5 |
| 14C-2400-G | 40 | 5484 | 4.44 |
| 14C-2630-G | 63 | 26523 | 7.16 |